CH-HMI-01 AUTO AREA: SALT LAKE CITY, UT ALARMS: 0 --:--:--
OPERATOR · CH-001

Connor Hardy

Controls Engineer @ CleanJoule

This is my playground: a server in my house running whatever seemed fun to build. Play me at chess, tune a reactor loop, or read what the night-shift AI had to say. By day I make machines talk to each other; new things show up here as I build them.

PLANT STATUSLIVE · HOMELAB
TI-101 CPU
--°C
TI-102 GPU
--°C
JI-101 LOAD
--
MI-101 RAM
--%
XI-101 SVCS
--
KI-101 UPTIME
--
Real readings from the server in my house that is serving you this page. Updated every minute.

02 · Correspondence chess

UNIT: CHESS · CONNOR PLAYS BLACK-- ACTIVE
♞︎

Challenge me to a slow game. You're White: make a move, get a game code, and come back whenever. I'll get a ping on my phone and reply within a day or two.

RECORD (W–L–D): --
Challenge Connor →

03 · Tune my loops: reactor R-301

LEVEL 1 · SINGLE LOOP · TIC-300 · REVERSE ACTINGAUTO
SP setpoint PV reactor temp CV cooling %
SP60.0
PV--
CV--
Whoever tuned this was in a hurry. Calm it down, then hit Exotherm!
LEVEL 2 · CASCADE · TIC-301 → TIC-302 · REACTOR R-301CAS
← CWS 5 °C from chiller ← CWR to chiller jacket return jacket supply M R-301 60.0 °C P-301 TV-302 28% cold TIC301 REACTOR PV 60.0 TIC302 JACKET PV 50.0 SP 50.0
Reactor SP Reactor TT-301 Jacket TT-302 Jacket SP TV-302 %
TIC-301 · OUTERreactor → jacket SP
TIC-302 · INNERjacket → valve TV-302
REACTOR--
JACKET--
VALVE--
Tip: real engineers tune the inner loop first. Flip TIC-301 to MAN, bump the jacket SP, and get TIC-302 snappy. Then go back to CAS.

04 · P&ID: how this page gets to you

YOU browser HTTPS V-201 Cloudflare edge FV-301 tunnel · fail-closed SRV-401 homelab i7-6700K 64 GB · GTX 1070 Ubuntu + Docker ● running WEB nginx :80 No open ports at home: the tunnel dials out to Cloudflare, so nothing on the internet can dial in.

05 · Operator file

CH-001 Connor Hardy · Controls Engineer @ CleanJoule · open file ▾

Event log

DATETAGEVENTSTATE
2024-10EV-006Controls Engineer · CleanJouleSalt Lake City. Leading a small controls team through a factory build-out at an early-stage industrial startup: Allen-Bradley PLCs, Ignition SCADA, MSSQL historians, industrial networks.ACTIVE
2022-06EV-005Sr. Controls Engineer · Purple InnovationsGrantsville. Kept 50+ Emerson and Allen-Bradley PLCs and HMIs running; designed and installed new production lines and machine retrofits.CLEARED
2022-01EV-004Control Systems Engineer · Plug PowerLatham, NY. PLCs, HMIs and I/O for portable hydrogen electrolysis units.CLEARED
2021-06EV-003Control Systems Engineer · Thermo SystemsCommissioned 1,500+ sensors and actuators for a hyperscale data center HVAC system; P&IDs, I/O schematics, sequence-of-operations testing.CLEARED
2021-05EV-002B.S. Chemical Engineering · University of UtahMinor in Nuclear Engineering. Led the senior project: a sensor that measures aerosol particle mass flow rate.LATCHED
2018-05EV-001Process Control Engineer · Combustion R&D LabsFirst loop closed. OPTO22 controller programs for a research lab.CLEARED

Faceplates: recent projects

UDT-01

One SCADA for the whole factory

A unified Ignition Perspective platform: UDT hierarchy, MSSQL historian schema, and a site-aware tag structure that pulls independently built machines into one consistent system.

HS-02

Machines that shake hands

Handshake architecture for PLC-to-PLC communication between machines, plus the control plan and the team's PLC naming standard.

TIC-03

Reactor cooling, cascaded

Cascade PID cooling in function block diagram with split-range pump and fan control. (The loop above is its little cousin.)

FT-04

Commissioning day

Coriolis meters, mass flow controllers, VFDs and distributed I/O over EtherNet/IP and Modbus. Tuned condensing control on a glycol chiller.

AI-05

Local AI for controls

Fully local LLM workflows on an on-prem GPU workstation to take the repetitive work out of PLC and SCADA development.

I/O list

DI-001Allen-Bradley · Studio 5000 · CompactLogix
DI-002Ignition Perspective SCADA
DI-003MSSQL historians
DI-004EtherNet/IP · Modbus
DI-005Ladder & function block diagram
DI-006PID & cascade control
DI-007Emerson PLCs · OPTO22
DI-008P&IDs & electrical drawings
DI-009Class I Div 2 hazardous areas
DI-010Instruments, drives & VFDs
DI-011Team leadership & standards
DI-012Linux · Docker · local LLMs